Reference layout · modular builder
Every block
on one page.
The IMF website reference page shows styled Gutenberg and ACF blocks in one, two or three columns. Use them to build Company, Quality, Contact, Applications, News and Legal pages.


Case study · 12 September 2026
A custom pressure regulator,
from catalogue model to customer site.
An operator of hydrogen refuelling stations for heavy vehicles needed a pressure regulator that could deliver stable pressure from 700 bar storage outdoors at temperatures down to −40 °C. No catalogue model met all the requirements.
We started with the D973, our high-pressure regulator, rated for 700 bar inlet pressure with BSPP connections and 1,000 bar with 3/8″ OD SFX. We adapted it to low temperatures, the station’s pressure cycles and hydrogen leak-tightness requirements.
The specification.
| Parameter | Requirement |
|---|---|
| Fluid | Gaseous hydrogen |
| Inlet pressure | 700 bar |
| Ambient temperature | Down to −40 °C, outdoor installation |
| Body | 316L stainless steel |
| Leak tightness | Int. 10⁻³ · ext. 10⁻⁴ mbar·l/s, helium |
| Upstream filtration | 10 µm |
Five steps, fourteen weeks.
- Review the requirements with the operator and select the D973 as the starting model.
- Adapt the materials: 316L body, PCTFE seat and seals qualified for low temperatures.
- Machine and assemble the prototype in Andilly.
- Test helium leak tightness, pressure cycling and cold resistance.
- Complete site acceptance with the operator and hand over the documentation.

“Starting with a proven model let us focus on the two main changes: cold conditions and pressure cycling.”
IMF engineering team
What we learned
- Using a catalogue model as the starting point significantly shortens qualification.
- Cold conditions affect the choice of seals and seat as well as the body.
- Helium testing each component verifies hydrogen leak tightness.
Documents supplied
On request, we prepare 3.1 material certificates, a helium leak report for each component and the PED declaration of conformity during manufacturing and include them with the order.
Good to know
Air Liquide CTE tests a version for oxygen and medical gases. Mention your requirements when you enquire so that degreasing and the cleanliness certificate can be prepared during manufacturing.
Buttons & links
One set of buttons
for every background.
Three action levels in several sizes: primary, secondary and link. Start labels with a verb. An arrow indicates navigation and a download icon indicates a file.
Primary
Secondary
Download
Links
Primary
Light outline
Link
Layout
One, two or
three columns.
Each section uses a standard width of 1,520 px or a narrow width of 960 px and its own grid. Three columns become two on tablets. On phones, all columns stack in reading order.
An industrial SME in Andilly
Since 1964, IMF has designed and manufactured pressure regulators, valves and safety relief valves for industrial gases, hydrogen, nuclear and defence applications.
About IMFSix demanding sectors
Extreme pressures, reactive fluids and regulated markets. Each sector has its own constraints, standards and typical designs.
Our applicationsWorkshop
Machining, assembly and testing under one roof.
Engineering and production work side by side from drawing to test report.
Visit us

Choose by fluid
Air, nitrogen, helium, oxygen and hydrogen each require suitable materials, seals and precautions.
Read the guideFlow, Kv and sizing
Manufacturer flow rates are specified for air under sonic flow conditions. For another gas, apply a correction based on density.
Read the guideCleanliness, degreasing and oxygen
For degreased and oxygen versions: procedure, cleanliness class and packaging.
Read the guideThe factory
Designed and made in
Andilly since 1964.
Design, machining, assembly and testing under one roof: 1,750 m² in Andilly, 20 km from Paris.
Every component is marked, traceable to its configuration and helium-tested before it leaves the factory.
Visit us

Highlights
Figures, cards
and milestones.
Highlight blocks summarise an offer, evidence or timeline. They support three to six items and follow the 1,520 px grid.
- Expertise
- 60+ years
- Operating pressure
- 0 – 1 100 bar
- Temperature range
- −270 / +200 °C
- Customers
- 300+ in 65 countries
Engineering
We assess pressure, temperature and fluid, then recommend materials and a configuration, from a standard component to a custom assembly.
Testing
Actuated and manifold assemblies are function-tested in our workshop. The test report accompanies the order.
Support & audits
We carry out on-site audits to identify energy losses and likely failures, and provide support long after installation.
-
Quality management
ISO 9001:2015
The quality management system covers design, purchasing, machining, assembly, testing and after-sales service.
PDF certificate -
Pressure equipment
DESP 2014/68/UE
Pressure equipment placed on the European market: categories, conformity assessment and CE marking.
EU declaration -
Explosive atmospheres
ATEX 2014/34/UE
Equipment for explosive atmospheres. Specify the zone and we will propose a compliant design.
Milestones
Six decades and key milestones.
1948
The group's origins
AUXIM starts manufacturing pneumatic valves and enters the railway market in 1955.
1964
IMF is founded
High-precision pressure regulators for industrial gases in Andilly.
1965
Naval defence
First hydraulic and pneumatic control systems for submarines and surface vessels.
2000
PET blow moulding
The start of more than twenty years of blow-moulding components, now used on four continents.
2024
IMF International
IMF joins the group formed by merging fluid control manufacturers.
Documentation
What comes
with the equipment.
Available on request and archived with the order. Specify the documents you need when you enquire, so we can compile them during manufacture.
- Material certificates
- 3.1 certificates for bodies and wetted parts in brass, stainless steel, aluminium bronze, Monel and Inconel.
- Leak test report
- Internal and external helium test record for each component, with its serial number.
- Declarations of conformity
- EU declaration under PED or T-PED, depending on the application, with CE marking and category.
- ATEX zone statement
- Declaration of the zone and the compliant design supplied.
- Functional test report
- For every actuated or manifold assembly: cycles, setpoints, results and operator.
- Cleanliness certificate
- For degreased and oxygen versions: procedure, cleanliness class and packaging.
Interactive content
Expand, browse
and scroll.
Accordions, FAQs, galleries and sliders keep pages short while keeping information accessible. All support keyboard navigation and remain readable without JavaScript.
Body and internal materials
Brass or 316L stainless steel body, depending on the fluid. Select poppet inserts and seats for the fluid and pressure: PCTFE, PEEK, Torlon, Monel, stainless steel or copper.
- Brass
- 316L stainless steel
- PCTFE
- PEEK
- Torlon
- Monel
Outlet pressure ranges
This panel can contain a paragraph, list, table or button. See the product data sheet for each model’s pressure ranges.
Available connections
This panel can contain a paragraph, list, table or button. For example: BSPP, NPT or OD SFX connections, depending on the series.
Leak tightness and testing
This panel can contain a paragraph, list, table or button. For example: helium leak testing of each component before shipment.
Technical FAQ
Frequently asked questions
about H₂ regulation.
Common questions from integrators, engineering teams and operators. For more help, an engineer will take up your request within 24 hours.
Ask your questionWhat is the minimum leak-tightness requirement for a hydrogen pressure regulator?
For hydrogen we target internal leakage of 10⁻³ mbar·l/s and external leakage of 10⁻⁴ mbar·l/s, measured using helium on every component. The leak test report can accompany the order with the serial number.
How do you choose between a spring-loaded and a dome-loaded hydrogen pressure regulator?
[Answer to be supplied by IMF engineering: two to four sentences.]
Which materials resist hydrogen embrittlement?
[Answer to be supplied by IMF engineering: two to four sentences.]
Does a hydrogen pressure regulator require an upstream filter?
[Answer to be supplied by IMF engineering: two to four sentences.]
What does the “OD SFX” suffix on the D973 mean?
[Answer to be supplied by IMF engineering: two to four sentences.]
What are the lead times for standard and custom hydrogen pressure regulators?
[Answer to be supplied by IMF engineering: two to four sentences.]






Calls to action
Trusted by
- [Customer logo]
- [Customer logo]
- [Customer logo]
- [Customer logo]
- [Customer logo]
- [Customer logo]
News
Our publications
& news.
New products, trade shows and R&D partnerships. Follow the latest developments from our engineering team.
-

700 bar, −40 °C: a custom pressure regulator in 14 weeks
How our engineering team qualified a 316L stainless steel regulator for a heavy vehicle refuelling station, from specification to site acceptance.
-

ADES Technologies & IMF at InnoTrans 2026
Meet us to discuss rail industry projects and requirements for custom solutions.
-

The group expands its presence in China
Dedicated local representatives bring the group closer to its customers, partners and industrial projects.
Contact us
Switchboard & reception
+33 1 34 27 16 16 contact@imf-fluid.comMonday to Thursday: 8:00–17:30
Friday: 8:00–16:30.
Direct contacts
- Quotes & recommendationssales@imf-fluid.com
- Support & after-sales servicesupport@imf-fluid.com
- Orders, invoices and purchasingadmin@imf-fluid.com
- Careersrh@imf-fluid.com
Custom solutions
Working on a hydrogen project?
Send us the fluid, pressures, flow rate and temperature. Our engineering team will propose a model and configuration.
Need the complete catalogue?
Buttons & links
Buttons and links
in columns.
The same styles, using the editor’s native blocks.
Primary
Secondary
Downloads
Links
Primary
Light outline
Lien
Certifications
Quality & certificationISO 9001:2015
Quality management
DESP 2014/68/UE
Pressure equipment
T-PED
Transportable pressure equipment
ISO 19443
Nuclear quality management
ATEX 2014/34/UE
Explosive atmospheres